桥梁钢的力学指标要分两层看:室温拉伸决定承载能力,冲击韧性决定低温与动载下的抗脆断能力。A709 把后者写成了可执行的表格——按构件类型分 T/F,按服役温度分 Zone,按厚度分档,三者交叉查表才能得出一个可验收的数值。
Two layers matter: room-temperature tension for load capacity, and notch toughness for brittle fracture resistance. A709 turns the latter into tables indexed by member type (T/F), service temperature zone and thickness.
拉伸性能
Tensile properties| 牌号 Grade | 屈服 MPa | 抗拉 MPa | 8 in. 伸长率 | 2 in. 伸长率 | 备注 |
|---|---|---|---|---|---|
| 36 [250] | 250 | 400–550 | 20 | 23 | 抗拉区间 400–550 MPa,塑性与韧性储备较充裕 |
| 50 [345] | 345 | 450 min | 18 | 21 | 抗拉仅设下限,与欧标上限体系不同 |
| 50S [345S] | 345 | 450 min | 18 | 21 | 屈服设 345–450 MPa 区间,屈强比 ≤0.85/0.87 |
| QST 50 [QST 345] | 345 | 450 min | 18 | 21 | 以型钢供货,表面快冷后自回火,STT 595–705 ℃ |
| QST 50S [QST 345S] | 345 | 450 min | 18 | 21 | 屈服区间 345–450 MPa,屈强比 ≤0.85/0.87 |
| 50W [345W] | 345 | 485 min | 18 | 21 | 耐候指数 ≥6.0(G101),可裸用 |
| HPS 50W [HPS 345W] | 345 | 485 min | 18 | 21 | C ≤0.11%,S ≤0.006%,钙处理控制硫化物形态 |
| 50CR [345CR] | 345 | 485 min | 18 | 21 | Cr 10.5–12.5%,可裸用,对应 A1010/A1010M |
| QST 65 [QST 450] | 450 | 550 min | 15 | 17 | 屈服 450 MPa 级型钢,适合短跨重载 |
| QST 70 [QST 485] | 485 | 620 min | 14 | 16 | 屈服 485 MPa 级型钢,减薄效果明显 |
| HPS 70W [HPS 485W] | 485 | 585–760 | — | 19 | 抗拉 585–760 MPa,2 in. 伸长率 19% |
| HPS 100W [HPS 690W] | 690 | 760–895 | — | 18 | >65–100 mm 屈服降至 620 MPa,抗拉 690–895 MPa |
依据表 1;HPS 100W 厚度 >65–100 mm 时屈服降至 620 MPa、抗拉 690–895 MPa。Per Table 1; HPS 100W properties step down above 65 mm.
折减与屈强比
Adjustments and yield ratio两条折减规则必须记住。其一,钢板宽度超过 600 mm 时,伸长率要求下调 2 个百分点;其二,型钢翼缘厚度超过 75 mm 时,Grade 50 的 2 in. 伸长率按 19% 判定。折减只针对塑性指标,屈服与抗拉的下限不因尺寸放宽。
50S 与 QST 50S 另设屈强比上限:腹板取样时不超过 0.87,其他位置不超过 0.85。屈强比过高意味着材料在屈服后很快进入强化段,抗震与抗疲劳储备不足;这也是 50S 与普通 50 的核心区别之一。
Grade 36 有一个例外:截面积小于 1 in.²(645 mm²)的型钢与厚度小于 12.5 mm 的非扁钢棒材,制造厂可不做拉伸试验。这条豁免只适用于小规格,不能推广到大规格产品。
服役温度分区
Service temperature zones| 分区 Zone | 最低服役温度 Minimum service temperature | 典型地区 Reference |
|---|---|---|
| Zone 1 | 0 ℉ [−18 ℃] 及以上 | 温和气候、无严寒记录地区 |
| Zone 2 | 低于 0 ℉ 至 −30 ℉ [−18 至 −34 ℃] | 冬季低温但极端值有限的地区 |
| Zone 3 | 低于 −30 ℉ 至 −60 ℉ [−34 至 −51 ℃] | 高寒地区、山区与北部内陆 |
分区按最低服役温度确定,试验温度随之变化。Zones follow minimum service temperature; test temperature follows the zone.
非断裂控制构件(T 类)
Non-fracture-critical members (T)| 牌号 | 厚度 mm | Zone 1 | Zone 2 | Zone 3 |
|---|---|---|---|---|
| 36T [250T] | ≤100 | 15 [20] @ 21 ℃ | 15 [20] @ 4 ℃ | 15 [20] @ −12 ℃ |
| 50T [345T] | ≤50 | 15 [20] @ 21 ℃ | 15 [20] @ 4 ℃ | 15 [20] @ −12 ℃ |
| 50ST [345ST] | 50–100 | 20 [27] @ 21 ℃ | 20 [27] @ 4 ℃ | 20 [27] @ −12 ℃ |
| HPS 50WT | ≤100 | 20 [27] @ −12 ℃ | 20 [27] @ −12 ℃ | 20 [27] @ −12 ℃ |
| QST 65T [450T] | ≤50 | 20 [27] @ 10 ℃ | 20 [27] @ −7 ℃ | 20 [27] @ −23 ℃ |
| QST 70T [485T] | ≤50 | 20 [27] @ 10 ℃ | 20 [27] @ −7 ℃ | 20 [27] @ −23 ℃ |
| HPS 70WT | ≤100 | 25 [34] @ −23 ℃ | 25 [34] @ −23 ℃ | 25 [34] @ −23 ℃ |
| HPS 100WT | ≤65 | 25 [34] @ −34 ℃ | 25 [34] @ −34 ℃ | 25 [34] @ −34 ℃ |
表中数值为三个试样的平均吸收能量,单位 ft-lbf [J] 与试验温度。Minimum average energy, ft-lbf [J] at the stated temperature.
断裂控制构件(F 类)
Fracture-critical members (F)| 牌号 | 厚度 mm | Zone 1 | Zone 2 | Zone 3 |
|---|---|---|---|---|
| 36F [250F] | ≤100 | 25 [34] @ 21 ℃ | 25 [34] @ 4 ℃ | 25 [34] @ −12 ℃ |
| 50F [345F] | ≤50 | 25 [34] @ 21 ℃ | 25 [34] @ 4 ℃ | 25 [34] @ −12 ℃ |
| 50SF [345SF] | 50–100 | 30 [41] @ 21 ℃ | 30 [41] @ 4 ℃ | 30 [41] @ −12 ℃ |
| HPS 50WF | ≤100 | 30 [41] @ −12 ℃ | 30 [41] @ −12 ℃ | 30 [41] @ −12 ℃ |
| QST 65F | ≤50 | 30 [41] @ 10 ℃ | 30 [41] @ −7 ℃ | 30 [41] @ −23 ℃ |
| QST 70F | ≤50 | 30 [41] @ 10 ℃ | 30 [41] @ −7 ℃ | 30 [41] @ −23 ℃ |
| HPS 70WF | ≤100 | 35 [48] @ −23 ℃ | 35 [48] @ −23 ℃ | 35 [48] @ −23 ℃ |
| HPS 100WF | ≤65 | 35 [48] @ −34 ℃ | 35 [48] @ −34 ℃ | 35 [48] @ −34 ℃ |
F 类另设单值下限(如 50F 为 20 ft-lbf [27 J]),平均值与单值须同时满足。F grades also carry a minimum single-value requirement.
硬度、复验与试验频次
Hardness, retest and frequencyHPS 100W 除拉伸与冲击外,还须做布氏硬度试验,具体指标按表 1。硬度用于辅助判断调质工艺是否稳定,不能代替拉伸判定。
冲击试验频次按 A673/A673M 的 H 或 P 频次执行:T 类多为 H 频次,F 类与 HPS 系列多为 P 频次。F 类钢板的取样位置更密——轧态与控轧板在每张板的两端取样,正火板在一端取样,调质板在两端取样。频次与位置写错,整套冲击数据在监理审核时都可能被判无效。
复验规则分两类:普通牌号按 A6/A6M 复验;调质钢板可在重新热处理后复验,但全部力学性能须重做,不能只补做不合格项。
需要 A709 报价或技术资料?
提供牌号、T/F 标识、冲击分区、厚度、宽度、长度、数量与交货状态,即可获得规格确认与报价。
Need a quotation or technical documents? Send grade with T/F suffix, impact zone, thickness, width, length and quantity.